NBN3 F31K Z8 PEPPERL FUCHS Part number: 282690
Inductive sensor NBN3 F31K Z8 Z8 Direct mounting on standard actuators Fixed setting
Inductive sensor NBN3 F31K Z8 Z8 Direct mounting on standard actuators Fixed setting
Inductive sensor NBN3 F31K2M Z8L B33 S S Direct mounting on standard actuators Compatible with all process control systems 2 solenoid valves can be connected Weatherproof housing for outdoor applications Rugged metal base Temperature range 40 ... 167 °F ( 40°C to 75°C) 2 wire DC minimum off state current LEDs switching of Plug in terminals
AS Interface sensor actuator module VAA 4E4A G4 ZE E2 G4 ZE E2 Degree of protection IP65 Flat or round cable connection (via standardized EEMS base, not included with delivery) Cable piercing method for flat Communication monitoring, turn off Inputs 2 3 wire sensors Power supply of outputs from the external auxiliary voltage of inputs Function display bus, ext. voltage, Monitoring of overloads
AS Interface sensor actuator module VBA 1E3A M18 ZE E2 V1 ZE E2 V1 A B slave with extended addressing possibility for up to 62 slaves Input 2 wire Function display bus For screw mounting in almost all metric threads and PGs Unlimited addressing! Power supply of the inputs outputs from external auxiliary voltage Including M25 adapter to M18 x 1 connection to MOVIMOT
AS Interface sensor actuator module VBA 4E3A G4 ZE E2 G4 ZE E2 Degree of protection IP65 A B node with extended addressing possibility for up to 62 nodes Flat or round cable connection (via standardized EEMS base, not included delivery) Cable piercing method flat Inputs 2 3 wire sensors Power supply of outputs from the external auxiliary voltage of inputs Function display bus, ext. voltage, LED indicator overload on
Inductive sensor NBN3 F31K2M Z8L B13 S S Direct mounting on standard actuators Compatible with all process control systems Weatherproof housing for outdoor applications Rugged metal base Temperature range 40 ... 167 °F ( 40°C to 75°C) 2 wire DC minimum off state current LEDs switching of solenoid valve Plug in terminals
AS Interface sensor actuator module VBA 4E KE1 Z 4E Z A B node with extended addressing possibility for up to 62 nodes Housing removable terminals Communication monitoring Inputs 2 wire sensors and mechanical contacts Addressing jack Power supply of inputs from the Function display bus, external auxiliary voltage
Inductive sensor NBN3 F31K2M Z8L B13 S 3G 3D S 3G 3D Direct mounting on standard actuators ATEX IECEx Zone 2 22 Compatible with all process control systems 2 wire DC minimum off state current Rugged metal base Weatherproof housing for outdoor applications Plug in terminals
Inductive sensor NBN3 F31 Z8 V1 Z8 V1 Direct mounting on standard actuators Fixed setting LEDs for switching state of solenoid valve
Inductive sensor NCN3 F25 N4 V1 N4 V1 Direct mounting on standard actuators ATEX & IECEX certifications NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers